Ice Machine in Need of Cleaning
Ice Machine in need of cleaning. Ran through clean cycles. Dropping full ice sheets at approximately 24 minutes on 7/3/24 in Waco Texas.
Read More »
Found AC Divider Wall Frozen
Found AC divider wall frozen drain line transition from medium to low temp backing up drains. Heated line and cleared drain on 6/20/24 in Waco Texas.
Read More »
Repaired the Drain and Re-Insulated
Repaired the drain and re-insulated. Replaced fan delay and TEV. Removed majority of ice on floor on 6/6/24 in Waco Texas.
Read More »
Gas Inlet Valve was Not Set To Off
Gas inlet valve was not set to off. Set to off and replaced gas inlet valve on 6/5/24 in Waco Texas.
Read More »
Found Mini Split with Low Charge
Found mini split with low charge. tightened the line set flare and added 4 lbs of 410a on 5/28/24 in Hillsboro Texas.
Read More »
Blower was Not Rotating at Full RPM
Blower was not rotating at full rpm. traced to week spade connector on the capacitor. repaired. unit blowing full rpm again on 5/2/24 in Clifton Texas.
Read More »
TEV was not Feeding Properly
TEV was not feeding properly causing unit to freeze up. procure parts, I pumped down system, remove TEV, remove drier, install new, startup and verify operations on 3/20/24 in Waco…
Read More »
One of the Fans was Making a Loud Noise
One of the fans was making a loud noise on a Reach-in Freezer. I replaced the Evaporator Motor to solve the issue on 2/29/24 in Hillsboro Texas.
Read More »
Installed Refrigerant Line-Set from Condenser to Evaporator
Installed refrigerant line-set from condenser to evaporator. Cut penetration, run copper lines, evacuate to EPA standards, add r448a refrigerant, verify operations on 2/21/24 in Waco Texas.
Read More »