Found Unit Low on Gas
Found unit low on gas. Recharged unit. Found leaking seal cap at in line suction Shrader. Replaced cap, Unit cooling on9/24/24 in Waco Texas.
Read More »
Replaced TEV Valve on Ice Machine
Replaced TEV Valve on Ice Machine. System off on arrival. Chemically cleaned unit. Ran in freeze mode for extended testing on 9/5/24 in Waco Texas.
Read More »
Hoshizaki Ice Machine Dispenser Not Dropping Ice
Hoshizaki ice machine Dispenser not dropping ice. No power to switch. Traced to GFI outlet. Reset and now dispensing ice on 8/26/24 in Waco Texas.
Read More »
Fan Motor Seized Up
Fan motor seized up. Removed and replaced motor and door gaskets. Cleared drain on small arctic air cooler on 8/14/24 in Hillsboro Texas.
Read More »
WIF Frosted Over Solid
WIF frosted over solid. Defrost terminated to soon, bad timer; replaced. De-iced WIF and WIC coils. WIC frosted up due to plugged drain line. Cleared drain and d-iced. Drain was…
Read More »
Replaced Hoshizaki Ice Machine Pump
Replaced Hoshizaki Ice Machine Pump after a piece of ice deflection had seized the motor 8/9/24 in Waco Texas.
Read More »
Unit Frozen because of Bad Pump
Unit Frozen because of bad pump. Replaced Pump and replaced a stopped up water filter on 7/24/24 in Waco Texas.
Read More »
Removed Failing Digital Controller
Removed failing digital controller and replaced with standard mechanical. Retrofitted wiring. Put into defrost and verified heaters are working on 7/10/24 in Waco Texas.
Read More »
Found Evaporator Completely Iced Over
Found evaporator completely iced over. Plugged drain line and solid cover of mold on inlet coil caused freeze up. De-iced coil, cleared drain and washed off mold. System online and…
Read More »