Resolved a Walk-In Cooler Voltage Issue and Replaced a Rooftop Fan Motor at a Waco Restaurant 05.11.26
Clay · May 11, 2026 · Near Interstate 35, Waco TX 76706

A Waco restaurant's walk-in cooler wasn't holding temperature, and the freezer was cycling oddly. Clay traced both issues to fluctuating power supply voltage knocking the evaporator fans offline; once the voltage was stabilized, both units returned to normal operation. The freezer compressor oil showed a heavy amount of green leak-finder dye, so an oil change was recommended to re-establish a clean baseline for future leak detection. While confirming rooftop operation, Clay caught smoke from an RTU with a seized condenser fan motor and replaced the motor and run capacitor on site; a degraded contactor was flagged for replacement before peak summer load. For same-day commercial refrigeration and HVAC service across the Heart of Texas, call 254-272-2714. Texian Cold — Texas TACLA89963C, R290 Certified, Factory Authorized for Norlake and Master-Bilt.