Tuned Superheat and Defrost on a College Station Restaurant Cooler
Clay · July 16, 2026 · 175 Century Square Dr, College Station, TX 77840, USA

A College Station restaurant reported heavy frosting on a commercial refrigeration unit, so Clay traveled out to diagnose the buildup. On arrival the evaporator coils were clear, pointing toward the refrigerant circuit and defrost timing rather than airflow. Clay checked superheat, found it running six degrees off spec, and adjusted it back to the manufacturer target. He then reset the defrost cycles to 45-minute intervals with temperature termination so the unit ends defrost on actual coil temperature rather than a fixed timer. He also recommended replacing the coiled-loop controller now in use with a bulb-type temperature control for tighter regulation. For commercial refrigeration service across Central Texas, call Texian Cold at 254-272-2714. Texas TACLA89963C, R290 Certified, Atosa Authorized Service Tech.